BR1000G-IN Features

APC Power-Saving Back-UPS Pro 1000 with LCD, 230V, India

  • Adjustable voltage sensitivity Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
  • Adjustable voltage-transfer points Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
  • Audible alarms Provides notification of changing utility power and UPS power conditions
  • Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Battery replacement without tools Enables fast battery replacement, lowering Mean Time to Repair (MTTR).
  • Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
  • Boost and Trim Automatic Voltage Regulation (AVR) Eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress.
  • Building Wiring Fault Indicator This LED informs users of potentially dangerous wiring problems in the wall circuit.
  • Cold-start capable Provides temporary battery power when the utility power is out.
  • Dataline surge protection Provides protection of connected equipment from power surges on the data lines.
  • Disconnected battery notification Warns when a battery is not available to provide backup power.
  • Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • LCD graphics display Text and mimic diagrams that display modes of operation, system parameters and alarms.
  • Power-saving outlets Automatically cuts power to idle equipment to conserve electricity.
  • Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse.
  • Serial connectivity Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
  • USB connectivity Provides management of the UPS via a USB port (not available on all models).
  • User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Back-UPS ProFeatures & Benefits

Protection
  • Dataline surge protection Provides protection of connected equipment from power surges on the data lines.
  • Surge only outlets Protect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.
  • Battery and surge protected outlets Back up and protect your hardware and data during power outages, surges and spikes.
Marketing Features
  • LCD Status Display Provides key UPS status at a glance. Multiple status indicators with load and battery bar graphs.
  • Boost Automatic Voltage Regulation (AVR) Preserves battery life and maximizes runtime by correcting low voltages without discharging the battery.
  • Energy Management Function Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
  • Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • Battery-protected and surge-only outlets Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Safety
  • Safety-agency approved Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Availability
  • Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance
  • Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.
  • Transformer-block spaced outlets Protect equipment with input transformer blocks without blocking access to other receptacles.
  • Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging.
  • Cold-start capable Provides temporary battery power when the utility power is out.
  • Customizable voltage sensitivity Toggle between pre-determined voltage-transfer points depending on your power quality (high, medium or low sensitivity), maximizing useful battery life and protecting sensitive electronics.
  • Green mode Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
  • Customizable voltage-transfer points Adjust the voltage points (widen or tighten the range) where your UPS transfers to battery to maximize useful battery life and protect sensitive electronics.
  • Energy Management Function Energy saving feature automatically power off peripherals when the a master device, usually a PC, hibernates or is shut down. Power to peripherals is immediately restored when the master device wakes up or is switched on.
  • Boost and Trim Automatic Voltage Regulation (AVR) Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Serviceability
  • Simple battery replacement Increases UPS availability by allowing quick, easy battery replacement.
  • Resettable circuit breaker Easy recovery from overloads; no need to replace a fuse.

Output

  • Output power capacity 600Watts / 1.0 kVA
  • Max Configurable Power (Watts) 600Watts / 1.0 kVA
  • Nominal Output Voltage 230V
  • Efficiency at Full Load 84.0 %
  • Output Frequency (sync to mains) 50/60 Hz +/-1 Hz
  • Topology Line Interactive
  • Waveform type Stepped approximation to a sinewave
  • Output Connections (4) India 3-pin 6A (Battery Backup) (2) India 3-pin 6A (selector_surgetitle)
  • Transfer Time 8ms typical : 12ms maximum

Input

  • Nominal Input Voltage 230V
  • Input frequency 50/60 Hz +/- 3 Hz (auto sensing)
  • Input Connections India 3-pin 6A
  • Cord Length 1.52meters
  • Input voltage range for main operations 150 - 280 V
  • Number of Power Cords 1
  • Efficiency at Full Load 84.0 %

Batteries & Runtime

  • Battery type Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
  • Typical recharge time 7.4hour(s)
  • RBC Quantity 1
  • Extendable Run Time 1
  • Battery Volt-Amp-Hour Capacity 216

Communications & Management

  • Interface Port(s) USB
  • Control panel Multi-function LCD status and control console
  • Audible Alarm Alarm when on battery : distinctive low battery alarm : overload continuous tone alarm

Surge Protection and Filtering

  • Surge energy rating 680Joules
  • Data Line Protection Analog phone line for phone/fax/modem/DSL (RJ-11 connector), Network line - 10/100/1000 Base-T Ethernet (RJ-45 connector)

Physical

  • Maximum Height 301mm , 30.1cm
  • Maximum Width 114mm , 11.4cm
  • Maximum Depth 382mm , 38.2cm
  • Net Weight 11.35kg
  • Shipping weight 12.77kg
  • Shipping Height 381mm , 38.1cm
  • Shipping Width 229mm , 22.9cm
  • Shipping Depth 483mm , 48.3cm
  • Color Black
  • Master Carton Units 2.0
  • Master Carton Weight 27.2

Environmental

  • Operating Environment 0 - 40 °C
  • Operating Relative Humidity 0 - 95 %
  • Operating Elevation 0-3000meters
  • Storage Temperature -15 - 45 °C
  • Storage Relative Humidity 0 - 95 %
  • Storage Elevation 0-15000meters
  • Audible noise at 1 meter from surface of unit 45.0dBA

Conformance

  • Standard warranty 2 years repair or replace